Grandstream Networks GXW-410x Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Serwery komunikacyjne IP Grandstream Networks GXW-410x. Grandstream Networks GXW-410x User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 37
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Grandstream Networks, Inc.
Analog IP Gateway GXW-410x
4 or 8 FXO Ports w/Video Surveillance
GXW-410x User’s Manual
www.grandstream.com
Firmware Version 1.0.0.53 support@grandstream.com
Przeglądanie stron 0
1 2 3 4 5 6 ... 36 37

Podsumowanie treści

Strona 1 - Grandstream Networks, Inc

Grandstream Networks, Inc. Analog IP Gateway GXW-410x 4 or 8 FXO Ports w/Video Surveillance GXW-410x User’s Manual ww

Strona 2

For more information regarding this setup, email Grandstream technical support at [email protected] FEATURES GXW–410x is a next generation I

Strona 3

TABLE 3: GXW-410X SOFTWARE FEATURES GXW– 410x FX0 Analog Gateway Series IP settings GXW-4104: 4 ports; 4 SIP accounts w/ choice of 3 SIP Server pr

Strona 4 - WELCOME

CONFIGURATION GUIDE CONFIGURATION WITH WEB BROWSER The GXW-410x has an embedded Web server that will respond to HTTP GET/POST requests. It also has em

Strona 5 - PACKAGING

END USER CONFIGURATION Once this HTTP request is entered and sent from a Web browser, the GXW-410x will respond with a login screen. There are two de

Strona 6 - CONNECTING THE GXW-410X

DHCP hostname This option specifies the name of the client. This field is optional but may be required by some Internet Service Providers. Default is

Strona 7 - FXO port

TABLE 7: STATUS PAGE DEFINITIONS Hardware Revision Hardware version number: Main Board, Interface Board MAC Address The device ID in HEX format. Thi

Strona 8 - APPLICATION DESCRIPTION

TABLE 8: ADVANCED CONFIGURATION PAGE DEFINITIONS Admin Password Administrator password. Only the administrator can configure the “Advanced Settings

Strona 9

Firmware Upgrade & Provisioning This radio button will enable GXW-410x to download firmware or configuration file through either TFTP or HTTP. Via

Strona 10 - FEATURES

Syslog Level Select the ATA to report the log level. Default is NONE. The level is one of DEBUG, INFO, WARNING or ERROR. Syslog messages are sent base

Strona 11 - IP Transport

CONFIGURING THE FXO CHANNELS Configuring the FXO channels on the GXW – 410x is an easy process. Follow the GUI interfaces. The Device Status page t

Strona 12 - CONFIGURATION GUIDE

TABLE OF CONTENTS GXW-410X USER MANUAL WELCOME...

Strona 13 - ND USER CONFIGURATION

Stage Method Syntax - ch1-8:1; {all channels 1 to 8 are set to value 1 or 2} Stage method can be set to either 1 or 2. In simple words, if you need

Strona 14

TABLE 10: CHANNELS PAGE DEFINITIONS Note – The channels here are basically SIP endpoints that will act as clients registering to the SIP Server conf

Strona 15 - USER SETTINGS

DTMF Method This parameter specifies the mechanism to transmit DTMF digits. There are7 modes supported: in audio which means DTMF is combined in audio

Strona 16

DIAL PLAN The Dial Plan feature implemented is applicable for VOIP to PSTN calls only. You may configure a dial plan based on the following grammar:-

Strona 17

SIP Registration This parameter controls whether the GXW-410x needs to send REGISTER messages to the SIP Server. The default setting is “Yes”. Unreg

Strona 18

Force INVITE Session Timer can be refreshed using INVITE method or UPDATE method. Select “Yes” to use INVITE method to refresh the session timer. Ena

Strona 19 - ONFIGURING THE FXO CHANNELS

SAVING THE CONFIGURATION CHANGES Once a change is made, press the “Update” button in the Configuration Menu. The GXW-410x will display the following s

Strona 20

VIDEO SURVEILLANCE The GXW-410x can be used with an Analog Surveillance CCD Camera to perform video surveillance function. This application should be

Strona 21

FIGURE 7: SCREEN-SHOT OF VIDEO SURVEILLANCE* * PC client side running VLC as monitoring station Grandstream Networks, Inc. GXW-410x User Manual

Strona 22

FIRMWARE UPGRADE Our latest official release can be downloaded from: http://www.grandstream.com/y-firmware.htm. Firmware (or software) upgrades ca

Strona 23 - PROFILES

TABLE OF FIGURES GXW-410X USER MANUAL FIGURE 1: DIAGRAM OF GXW-410X BACK PANEL...

Strona 24

UPGRADE THROUGH TFTP To upgrade firmware via TFTP, set the field “Firmware Upgrade and Provisioning: Upgrade Via” to TFTP. The TFTP server can be co

Strona 25

RESTORE FACTORY DEFAULT SETTING WARNING! Restoring the Factory Default Setting will DELETE all configuration information of the phone. Please BACKUP

Strona 26 - EBOOTING FROM REMOTE

Examples of GXW-410x Configurations APPLICATION ONE: GXW CONNECTED WITH AN IP-PBX OR SIP SERVER Scenario: A business with a traditional phone system

Strona 27 - VIDEO SURVEILLANCE

APPLICATION THREE: GXW CONNECTED WITH AN IP-PBX OR SIP SERVER AND VIDEO SURVEILLANCE red for PPLICATION FOUR: USING A GXW FOR PURE IP- IP COMMUNICAT

Strona 28

GLOSSARY OF TERMS ADSL Asymmetric Digital Subscriber Line: Modems attached to twisted pair copper wiring that transmit from 1.5 to 9 Mbps downstream

Strona 29 - FIRMWARE UPGRADE

FQDN Fully Qualified Domain Name. A FQDN consists of a host and domain name, including top-level domain. For example, www.grandstream.com is a fully

Strona 30 - UPGRADE THROUGH TFTP

MTU A Maximum Transmission Unit (MTU) is the largest size packet or frame, specified in octets (eight-net. The maximum for thernet is 1500 byte. AT

Strona 31

UDP User Datagram Protocol (UDP) is one of the core protocols of the Internet protocol suite. Using UDP, programs on networked computers can send sho

Strona 32 - SIP Platform

WELCOME Thank you for purchasing the Grandstream GXW–410x IP Analog FXO Gateway. The GXW–410x is a cost effective, easy to use and easy to configure

Strona 33 - Anywhere in the world

PACKAGING Unpack and check all accessories. Equipment included in the package: daptor AFETY COMPLIANCES ant with various safety standards includin

Strona 34 - GLOSSARY OF TERMS

CONNECTING THE GXW-410X FIGURE 1: DIAGRAM OF GXW-410X BACK PANEL GXW-410x Power Supply FXO PortsLAN/WAN RJ-45 Ethernet Ports On/Off Switch VIDEO IN

Strona 35

FIGURE 2: DIAGRAM OF GXW-410X DISPLAY PANEL GXW- 410x Display FXO port TABLE 2: DEFINITIONS OF THE GXW DISPLAY PANEL Power LED Indicates Power.

Strona 36

APPLICATION DESCRIPTION A. IP PBX / SIP Server with GXW410x A SIP proxy server such as Asterisk or a SIP registrar server can be deployed with the GXW

Strona 37

versa. All you need to make sure is that the 2 gateways are able to locate each other (they should be on the same LAN or on Public IPs). GXW–400X &

Komentarze do niniejszej Instrukcji